KS Series - Seismic Rack Cabinets

Built on the successful KabinPLUS platform, KS Series seismic cabinets are designed to keep information technology equipment safe in facilities located in areas with high earthquake risk.

Consistency In Features

All standard features of KD Series cabinets such as door perforation, color options, outer dimensions are also preserved in KS Series seismic cabinets. Single-point or 4-point perforated doors can be selected. Both types of door options have successfully passed seismic tests. Same cable management and airflow management accessories or ones with similar structure can be selected.

19-inch-montaj-profilleri

Adjustable 19 Inch Mounting Frame

• Welded heavy gauge steel 19 inch mounting frame
• Front and rear mounting frames are independentlyadjustable with 25 mm steps in depth axis
• Equipment mounting depth between front and rearmounting frames can be changed. (A)
• Design with welded mounting frames eliminate fixingat mid-height to the frame, which provides more spacefor cabling and air flow management accessories. (B)

sabitleme-ve-ankraj

Attachment and anchorage

For achieving seismic resistance, as important as the standalone cabinet design and certifications are, it is equally important to ensure that the cabinet is properly attached to the particular building.


Seismic cabinets shall be attached to the building by following rules described in their installation manual, which is prepared by their manufacturer mimicing type-test arrangement.

Fixing and anchoring elements used must have seismic resistance certificate.

uluslararasi-gecerli-sismik-sertifikasyon

Internationally Valid Seismic Certification

KS Series seismic cabinets have been tested and certifiedby internationally accredited laboratories for complience tofollowing standards

• IEC / EN 61587-2 
• IEC / EN 60980 Zone 4 (Nuclear facilities)
• Telcordia NEBS GR63 Zone 4
Group of cabinets attached with seismic stand accessories
on shake table mimicing data center aisle application

Seismic Accessories

Designed for use in raised floor applications “Seismic Base Stand” accessory is tested for its seismic resistance and certified.


All door and side panel options for KD and KS Series cabinets have been tested for their seismic resistance. During tests none of them have been opened or deformed. Both one-point and four-point locking types or split type doors can be selected in seismic cabinets. Similarly, fixed type or hinged type side panels can be used.

Level Adjustment

In aisle applications, all cabinets must be fixed to the floor at the same height to ensure proper positioning of airflow management accessories.


The base frame of KS Series cabinets can be separated from the cabinet framework (or delivered separately) and fixed to the concrete floor or seismic base stand by adjusting their level in advance. After this comparably easy process, each cabinet framework can be fixed to its own base frame and easily bayed to each other.

Server Kabinet 2Server Kabinet 3
  • Compatible with EN 60297-3-100 and EIA-310D for 19 inch equipment mounting
  • Tested and certified by internationally accredited laboratories for complience to IEC / EN 61587-2, Telcordia NEBS GR63 Zone 4, IEC / EN 60980 (Nuclear facilities),
  • Grounding and protection circuit comply with EN 60950.
  • Mounting rails, top panel, side panels and doors are electrically bonded to the cabinet frame. Additional grounding terminal is fixed on the frame for common bonding network connection.
  • Perforated doors have 85% relative open area - calculated in compliance with DIN 24041 Perforated Plates Standard
  •  Unless otherwise stated standard packaging is used.
  • Cabinet framework and two sets of welded mounting frames thatcan be adjusted independently in depth axisare made of steel.
  • Both front and rear mounting frames have unit indication markings.
  • Grounding terminal bracket for connecting to common bonding network
  • Top cover - with one (1) pc. brushed cable entry accessory
  • Side panels Standard; set of two (2) fixed panels
         Option 1; set of two (2) lockable and hinged panels
  • Front and rear doors - with standard swinghandle lock
         Standard; full-width curved perforated front door and split perforated rear door
    Option; full-width curved perforated front and rear doors
  • • Bottom cover Standard; none
         Option 1; full-covered with knockouts 
         Option 2; partially-covered for air flow management

Server Cabinet

Width

Height

Depth

600 mm 

42U - 2000 mm 

1000 mm

47U - 2200 mm

1100 mm

1200 mm

Network Cabinet

Width

Height

Depth

800 mm

42U-2000 mm

1000 mm

1000 mm

47U-2200 mm

1100 mm

1200 mm

ks-serisi-standart-olculer